Features
- Each output is over-current, short circuit and thermal overload protected
- Outputs programmable in 1 A steps
- Outputs controllable via a combination of switch inputs, CAN messages and logic functions
- Switch inputs ranging from 0 to 51 V, resolution 0.2 V
- Performing up to 200 logic operations using operators like Flash, Pulse, Set/Reset, Hysteresis, Toggle, And, Or, Less than, Greater than, Not equal to, Equal to, True, False etc.
- Performing functions such as flashing indicator lights and controlling thermofan and fuel pump
- Using logic functions to selectively turn off systems during low battery voltage or engine starting, reducing drain on the battery
- Providing full diagnostic information, including output currents and voltages, input voltages, and error status
- Transmitting diagnostic information via CAN to a display or data logging device or monitoring directly on a PC
Specifications
Outputs
- 8 x 20 A outputs – 20 A continuous, 115 A transient (typical)
- 24 x 8 A outputs – 8 A continuous, 60 A transient (typical)
Inputs
- 23 x Switch inputs
Communications
- 1 x CAN
Diagnostic Information
- Output current and voltages
- Input voltages
- Error status
Physical
- Connectors
- 1 x 37 pin Autosport connector
- 1 x 26 pin Autosport connector
- 1 x 1 pin Autosport connector
- 1 x 8 pin Autosport connector
- Case size 180 x 60 x 28 mm
- Weight 405 grams

MoTeC C185
MoTeC GP Lite Package licence only
MoTeC C187
M1 Development Licence V1.4.1 SL Library
MoTeC C127
M1 Development Licence V1.4.1
Level 2 Data Logging
MoTeC M1 M190 ECU
MoTeC C1812
MoTeC M1 M150 ECU
MoTeC M1 M170 ECU
MoTeC M1 Development
MoTeC M1 M182 ECU DI
MoTeC M1 M142 Electronic Control Unit DI 